This website works better with JavaScript
Strona główna
Odkrywaj
Pomoc
Zarejestruj się
Zaloguj się
cere
/
home
Obserwuj
1
Polub
0
Forkuj
0
Pliki
Problemy
0
Oczekujące zmiany
0
Wiki
Drzewo:
77d89f8742
Gałęzie
Tagi
master
home
/
domoticz
dirkse
bcfea565fd
some fixes
8 lat temu
..
Dockerfile
68566bed70
upped domoticz
8 lat temu
domoticz_linux_armv7l.tgz
68566bed70
upped domoticz
8 lat temu
readme.md
bcfea565fd
some fixes
8 lat temu
readme.md
RFXCom
hardware: RFXtrx433E
The preferred firmware for the RFXtrx433E is Ext or Ext2.
ext1 versus ext2
see 2.2.2 in
http://www.rfxcom.com/WebRoot/StoreNL2/Shops/78165469/MediaGallery/Downloads/RFXtrx_User_Guide.pdf
we are using ext1,
activated protocols:
RSL/Revolt
Oregon Scientific
Lighting4 (brennenstuhl receive)
unclear if we need this (enabled by default):
AC
ARC
X10
Brennenstuhl
learn with lighting5 in rfxcom-mgr
type: Kangtai, Cotech
send "Command on"
we have used the remote for learning (and picked the ID from ligting4 logs)
learn button at bottom of device
3 seconds for learn, 6 seconds for reset
3 devices
ID: AD 4A (probably the factory passwd for the included remote)
UNIT 1 (remote A) and 2 (remote B) are indoor
UNIT 4 (remote D) is the outdoor one
registered in domoticz via switch/learn